Installation manual

Rinnai Australia 14 Energysaver® - Operation & Installation Manual
Overheat Switch:
This device automatically shuts the gas supply off if the heater exceeds a predetermined temperature.
This is normally caused by an obstruction in front of the louvres, or a blocked fan filter.
If the overheat switch operates, turn the unit ‘OFF’, remove the obstruction (clean filters) and allow the
unit cool off for 10-15 minutes before re-operating.
Fusible Links:
The fusible link activates under conditions of severe overheating and shuts off the gas supply.
A service call will be required to repair the appliance.
Flame Failure Device:
If the flame goes out during operation this device shuts off gas to the burner. To reset, turn the unit ‘OFF’,
then ‘ON’ again. If this happens repeatedly a service call is required.
Electrical Fuse:
The electrical circuits are protected by an electric fuse. When the fuse blows, the heater will not operate.
The fuse must be replaced by an authorised person.
Power Failure:
In the event of a power failure or power cut, the gas valves will automatically close. After the power is
re-instated the appliance will automatically re-start. The time of day will need to be reset to the correct
current time (refer “SETTING THE CLOCK” on page 10).
Rinnai Australia has a service and spare parts network in all states. Our service network personnel are
fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs
servicing, please ring one of the service contact numbers on the back of this booklet.
Rinnai recommends that this appliance is serviced every 2 years.