Specification guide Heating
About this guide This guide has been written to help you select and order the right Rinnai heating system and associated components for the right job. This information is not intended as an installation guide. Rinnai is constantly improving its products, and as such, information and specifications are subject to change or variation without notice. For the most upto-date information go to www.rinnai.co.nz.
: s t n e t n co Heating range.................................................................4 Appendices Choosing the right type of heating.................................5 Appendix 1: Running costs...............................................30 Location considerations..................................................6 Appendix 2: Calculating the minimum room size............32 Rinnai iHeat: Determining suitability..............................
Heating range Rinnai provide fast and reliable heating. Hallmarks of our product range are precise temperature control and energy efficient heating. Energysavers These are fixed power flued heaters. Rinnai appliances flued via a power flue are approved by the sensitive choice programme of the Asthma Foundation.
Choosing the right type of heating Considerations such as geographical location, room size, room insulation, running costs, and functionality versus aesthetics all play a part in choosing the right heating solution. Geographical location Where you live in New Zealand can determine the type of heating solution you choose. Use the diagram below to work out which climate zone you are in. Room size Consider the whole area you need to heat.
Location considerations Clearances All Rinnai appliances are subject to clearances. Examples for the Energysaver 559FT and Portable Convectors are shown on this page. For additional clearance details, refer to the specific product pages in this guide. Fixed ventilation Rinnai Portable Convectors and Indoor Super Ray heaters (unflued appliances) draw the air for combustion from the room, so there is a need for adequate ventilation.
Rinnai iHeat®:Determining suitability Spending time in the planning stages and discussing the heating requirements with the customer will ensure the correct system is specified and that the Rinnai iHeat can be successfully installed.
Rinnai heating solutions Product specification pages
Energysavers Rinnai Energysaver®codes Gas Type Energysaver 309FT Energysaver 561FT Energysaver 559FT Energysaver 1004FTR NG RHF309FTWN RHF561FTWN RHF559FTWN RHF1004FTRWN LPG RHF309FTWL RHF561FTWL RHF559FTWL RHF1004FTRWL Flueing Flue is not supplied with the heater and must be ordered separately Direct A flue supplied with heater Description High efficiency power flued convection heater (room sealed appliance) with programmable timers.
Energysaver specification summary Energysaver 309FT Energysaver 561FT Energysaver 559FT Energysaver 1004FTR Colour White with grey louvres White with grey louvres White with grey louvres White with grey louvres Efficiency 80% 81.8% 79% 80% Energy star rating 4.3 star energy equivalent 4.8 star energy equivalent 4.3 star energy equivalent 4.
Energysaver dimensions (mm) Rinnai Energysaver 561FT Rinnai Energysaver 309FT 465 545 257 262 177 85 85 695 750 172 Gas Inlet 350 335 Gas Inlet 124 114.5 Rinnai Energysaver 559FT 760 Rinnai Energysaver 1004FTR 315 257 172 200 85 115 582 Air Filter 330 357.
Energysaver flueing guidelines Every Energysaver heater requires a flue system that will draw effectively and clear flue products safely under all potential wind and climatic conditions. It is the responsibility of the installer to ensure that the appliance is provided with an effective flue. Some guidelines to assist with flue design are listed below. These must be read and modified as necessary with reference to the particular installation. Flue terminal locations Must be compliant with AS/NZS 5601.1.
Energysaver flueing options Flueing option Description Flue components needed Direct and direct extended flueing Direct through-the-wall flueing for walls 75-385 mm thick. Flue can be extended if wall thickness is greater than 385 mm using the ESDFK and additional lengths of ESPIPE900. A: Direct - R1350, mushroom flue kit for walls 75-115 mm - R1351, mushroom flue kit for walls 115-240 mm - ESDFK1, straight horiz.
Energysaver flue components 50 mm Wall thickness 75-115 mm 50 mm 92 mm approx. Wall thickness 115-240 mm 92 mm approx. Direct AA mushroom flue kit Direct A mushroom flue kit Code Code = R1350 For use in walls 75-115 mm thick (can be cut to size). This is a complete kit, no other components are required. • • Stainless steel Inbuilt 2° fall to drain condensate = R1351 For use in walls 115-240 mm thick— typically weatherboard construction (can be cut to size).
120 Drain tube Ø 80 Top plate bracket Pipe locating spacer Wall spacer plate 120 Vermin plate Flue transition / condensation trap Grommet (Use with 1004) Mounting Strip Wall Clip Silicon Grease Ø 75 Vermin Plate Mounting/Securing Screws x9 Energysaver flue adaptor kit in-wall 45 ° flue bends (x2) Code Code = ESKIT03 Two 45 ° bends used to facilitate between horizontal, vertical, and downwards flueing. Two spacers included. Can be used separately, or together as one 90 ° bend.
approx. 155 mm Condensate trap Elbow adaptor Steel flue guard Code Code Code = ESCONDK Required for any vertical installations to ensure condensate generated during combustion is trapped and prevented from entering the combustion chamber of the heater. Supplied with a drain tube (not pictured). Typically only needed for through-wall vertical extension flueing installations. = ESELBOWB = R1370 Protection against hot flue gases when the flue terminates low to the ground.
Portable Convectors (unflued) Rinnai Portable Convector codes Gas Type Dynamo Avenger NG RCE471TRWHN RCE671TRWHN LPG RCE471TRWHL RCE671TRWHL Description Portable unflued (connected to gas supply via a wall or floor socket) fan convector heater supported by electronic timers and controls. Operated via remote or touch pad on top of the unit. Suitability Portable Convectors are unflued appliances and are not suitable for; bedrooms, bathrooms, toilets, saunas, spa rooms, or hallways.
Portable Convector specification summary Dynamo RCE471 Avenger RCE671 Colour White with grey louvres White with grey louvres Efficiency* 100% 100% Energy star rating 5.8 star energy equivalent 5.8 star energy equivalent Gas connection ⅜ ” MI BSP into 1.5 metre flexible gas hose with bayonet connection ⅜ ” MI BSP into 1.5 metre flexible gas hose with bayonet connection Heating area: - warm zone - medium zone - cool zone 51.5 m² 45 m² 38 m² 95 m² 80 m² 70 m² Minimum room size 37.5 m3 62.
Portable Convector accessories Wall socket stainless steel Wall socket stainless steel Gas bayonet socket Code Code Code = R2580WS Flush wall socket stainless steel finish. = R2580WW Flush wall socket white finish. = R2588S Floor or wall socket―chrome finish. Mushroom hose 10 mm Code = R2586HM Flexible connection hose (10 mm) to fit into a gas wall or floor socket. Typically used to replace yellowing or aged connection hoses in existing installations.
Super Rays Rinnai Super Ray codes Gas Type Indoor Super Ray 16 Electronic Manual Indoor Super Ray 24 Electronic Manual Indoor Super Ray 40 Electronic Manual Outdoor Super Ray Manual only NG WEA16N WMA16N WEA24N WMA24N WEA40N WMA40N ODHRAD3MN LPG WEA16L WMA16L WEA24L WMA24L WEA40L WMA40L ODHRAD3ML Electronic/manual refers to how the unit is switched on. Electronic uses a switch and manual uses a pull-cord.
Super Ray specification summary Indoor Super Ray 16 Indoor Super Ray 24 Indoor Super Ray 40 Outdoor Super Ray 100% 100% 100% 100% ½ “ (12.7 mm) copper flare union ½ “ (12.7 mm) copper flare union ½ “ (12.7 mm) copper flare union ½ “ (12.7 mm) copper flare union ⅜ “ (9.52 mm) copper flare union ⅜ “ (9.52 mm) copper ⅜ “ (9.52 mm) copper ⅜ “ (9.
Super Ray clearance information It is critical to the safe operation of this appliance that the clearances are maintained so the heater does not become a fire hazard. The Super Ray heaters discharge products of combustion from the top of the unit which could cause damage or discolouration to the ceiling if the ceiling clearances are not maintained.
Indoor Super Ray with a heat shield C B A With a heat shield fitted heat is deflected down and out so the side clearance needs to increase from 0.5 m to 1 m. WMA/WEA 16 WMA/WEA 24 2.5 m 2.7 m WMA/WEA 40 3.4 m A Approximate height from floor to bottom of burner (Rinnai recommend) B Side clearance from mounting bracket 1.0 m 1.0 m 1.0 m C Ceiling clearance from top of mounting bracket 0.5 m 0.5 m 0.
Indoor Super Ray accessories: Heat shield Rinnai Indoor Super Ray heat shield codes Indoor Super Ray 16 Indoor Super Ray 24 Indoor Super Ray 40 WHS16 WHS24 WHS40 Description Constructed from stainless steel and heat resistant insulator board, the Rinnai Super Ray heat shield acts as a deflector and insulator when fitted to an Indoor Super Ray heater. This has the benefit of reducing ceiling clearances, giving the owner flexibility about where the Super Ray heater can be positioned.
Indoor Super Ray accessories: Deluxe surround Rinnai Indoor Super Ray deluxe surround codes Indoor Super Ray 16 Indoor Super Ray 24 Indoor Super Ray 40 R1446 R1447 R1448 Description Designed as an aesthetic cover for the Indoor Super Ray heaters to make them look less industrial. Typically used in restaurants where overall design is important. Suitability All Rinnai Indoor Super Ray (WMA/WEA) radiant heaters. The deluxe surround fits onto the back of the appliance.
Rinnai iHeat Rinnai iHeat central heating code RAHU20 Description The Rinnai iHeat is a ducted home heating system that uses hot water from the Rinnai INFINITY continuous flow gas hot water heater to warm air and circulate it around the home. The Rinnai iHeat is controlled via a wall thermostat that has three fan speed settings and can be programmed to run on timers. How it works The Rinnai INFINITY continuous flow gas hot water heater provides hot water to the iHeat air handler unit (heat exchanger).
Rinnai iHeat specification summary Rinnai iHeat Energy efficiency Approximately the same as the Rinnai INFINITY―over 80% depending on the Rinnai INFINITY model and ducting used. Heating area: Warm zone: 333 m², medium zone: 285 m², cool zone: 250 m² The heating area in each house will vary due to amount of insulation, number and size of widows, floor structure etc. Minimum pipe size This is CRITICAL to the successful performance of the central heating system.
Rinnai iHeat accessories Rinnai iHeat fittings kit Rinnai iHeat suspended mount kit Code Code = R5046 Designed to simplify and speed up the iHeat installation process and to fit within the Rinnai INFINITY pipe cover.
Rinnai heating Appendices
Appendix 1: Running costs Running costs can play an important part in the purchase decision. Based on the information in the table below, calculate for yourself the approximate running cost of a Rinnai appliance, and approximate hours a 45 kg LPG bottle will last. Rinnai appliance Energysavers Gas Energy consumption output (MJ/H) (kW/h) 45 kg bottle Running costs per hour ($) will last LPG Natural Gas (hrs) $97 per 45 kg $0.
Rinnai iHeat running costs Running costs for the Rinnai iHeat are still being collated as we are trying to base the information on 'real' installations around the country. Once the information has been finalised it will be loaded on the Rinnai website—refer to the iHeat product within the heaters category on www.rinnai.co.nz. Running cost assumptions and calculations LPG gas bottle energy calculation 1 kg of LPG gas contains 50.4 MJ of energy 1 kW = 3.
Appendix 2: Calculating the minimum room size Height Unflued heaters must not be installed in rooms smaller than specified (refer to product specification page). To determine if the intended room meets the minimum size requirement multiply the height x width x length of the room. Len g th W t id h Example If the room dimensions are 5.3 m (length), width 5 m, and height 2.4 m then the volume would be 63.6 m3 and suitable for use with an Avenger RCE671 (minimum room size of 62.5 m3).
Appendix 3: Energysaver 1004FTR remote wiring diagram Remote switching kit: R1347. Rinnai does not supply the timers or transformers. Timer or manual switch Switch circuit power supply 24 V AC Must be AC black black white red blue Sub PCB Terminal block Rinnai Energysaver 1004FTR Rinnai Energysaver 1004FTR When a 24 Volt AC supply is applied to the sub-PCBs the appliances will turn on. When the 24 Volt AC power supply is disconnected appliances will turn off.
Appendix 4: Definition of an outdoor area This appliance shall only be used in an above ground open air situation with natural ventilation, without stagnant areas, and where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.