Specifications

Model 2402www.rinnaiamerica.com 3 0
INSTALLER’S INSTALLATION INSTRUCTIONS
Electrical Connection Notes
WARNING: The Continuum 2402 must be electrically grounded in
accordance with local codes or in the absence of local
codes with the most recent edition of the National Electrical
Code, ANSl/NFPA 70. In Canada, all electrical wiring to the
Continuum 2424 should be in accordance with local codes
and the Canadian Electrical Code, CSA C22.1 Part1. Do not
rely on the gas or water piping to ground the metal parts of
the water heater.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify correct operation after servicing.
1 The Continuum 2402 requires 120VAC/
60 HZ. Power from a properly
grounded circuit, GFl.
2 An on/off switch must be provided and
installed for the incoming 120VAC
power.
3 Wire the Continuum 2402 exactly as
shown in the wiring diagram on the
next page and on the inside of the
cover panel. The blue wire is the hot
leg wire; the brown wire is the neutral
wire.
4 A green screw is provided in the
junction box for the grounding
connection.
Your disconnect switch should be a type
that is suitable for outdoor use. Check
National Electrical Codes for proper type
switch to use in your area.
Ground
ON/OFF
PCB