Installation Guide
Polypropylene (PP) Common Venting Installation Instructions            5 
Copyright © 2018 Rinnai America Corporation. All Rights Reserved.  
High Altitude Installations 
Tankless water heaters using common venng at altudes over 2,000 Ft will automacally derate according to the 
tables below. Use the tables below for calculang your total BTU for mulple tankless water heaters.  
•  High altude installaons are cered up to 10,200 Ft (3,109 m).  
•  Reference the respecve Rinnai Tankless Water Heater Installaon and Operaon Manual to set the water 
heater up for the altude at which they will be operang.  
High Altude Derate 
PROPANE (LP GAS) 
Number 
of Water 
Heaters 
2,001 - 
5,200 Ft 
5,201 -  
7,700 Ft 
7,701 -  
10,200 Ft 
1  168,000   151,000   120,000  
2  332,640   298,980   237,600  
3  493,920   443,940   352,800  
4  651,840   585,880   465,600  
5  806,400   724,800   576,000  
6  957,600   860,700   684,000  
7  1,105,440   993,580   789,600  
8  1,249,920   1,123,440   892,800  
NATURAL GAS 
Number 
of Water 
Heaters 
2,001 -  
5,200 Ft 
5,201 -  
7,700 Ft 
7,701 -  
10,200 Ft 
1  170,000   153,000   139,000  
2  336,600   302,940   275,220  
3  499,800   449,820   408,660  
4  659,600   593,640   539,320  
5  816,000   734,400   667,200  
6  969,000   872,100   792,300  
7  1,118,600   1,006,740   914,620  
8  1,264,800   1,138,320   1,034,160  
 Must Do  
•  You must use vent components that are cered 
and listed with the water heater model. 
•  The vent system must vent directly to the outside 
of the building and use outside air or room air for 
combuson. 
•  Avoid dips or sags in horizontal vent runs by 
installing supports per the vent manufacturer’s 
instrucons. 
•  Support horizontal vent runs a minimum of every 
four feet and all vercal vent runs a minimum of 
every six feet. 
•  Venng should be as direct as possible with a 
minimum number of pipe ngs. 
•  Vent connecons must be rmly pressed together 
so that the gasketed form an air ght seal. 
•  Vent components connected to the water heater 
must be secured with one self-tapping screw, do 
not use any glues or solvents to connect vent 
components to the water heater. 
•  Set the temperature seng on all water heaters 
being common vented to the same temperature. 
•  Unless recovering a tank, Rinnai recommends 
electronically connecng with common venng 
and where water heaters are in a manifold system. 
Refer to the Rinnai installaon and operaon 
manual for addional details on electronically 
connecng mulple water heaters.  
•  Refer to the appendix of this manual for Ubbink 
vent component assembly and installaon 
instrucons. 