Recommended Spacing of Water Heaters 
Spacing of the water heaters is crical for the common 
vent system to mounng easily and securely. The 
common vent headers are made for 20.5” spacing (center 
line to center line) between water heaters.  If a dierent 
spacing is needed, please contact Rinnai concerning your 
applicaon. Rinnai recommends using the Tankless Rack 
System (TRS) which is designed for 20.5” spacing. The 
engineered system is designed to make installaon simple 
and greatly reduces installaon me. 
Custom Water Heater Spacing 
If common venng with LESS than 20.5” between water heaters: 
•  The installer assumes all responsibility of following local codes. Inspectors can reject the installaon if the 
rang plate cannot be seen for all water heaters.  
•  The Exhaust Header and 3” Diameter Extension Pieces must be cut appropriately to maintain the required 
3° slope. 
If common venng with GREATER than 20.5” between water heaters: 
•  The vent extension and 3” Diameter Extension Pieces must be cut to the appropriate length between to 
maintain a 3° slope.  
•  The length of each addional vent extension must be considered in the maximum allowable vent length. 
Exhaust Vent Installaon Procedures: 
 To maintain a 3° slope, use the following 
formula to calculate 3” Diameter Extension 
Piece length (L): 
(L) = (water heater spacing) X 0.05 
Example: if the adjacent water heater is 
20.5” away  
Length (L) = 20.5” x 0.05 = 1.02” 
Example: if the adjacent water heater is 26” 
away 
Length (L) = 26.0” x 0.05 = 1.30” 
20.5” 
Vent extension 
cut to size 
Air Intake 
extension 
3” Diameter 
Extension Piece 