Installation Guide
Polypropylene (PP) Common Venting Installation Instructions            24 
Copyright © 2018 Rinnai America Corporation. All Rights Reserved.  
Exhaust Vent Terminaon Clearances 
Other than direct vent, when using room air for combuson, you must install terminaons to expel exhaust. 
SNOW
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line
Canadian Installations 
(CSA B149.1) 
U.S. Installations 
 (ANSI Z223.1 /NFPA 54)  
Ref  Description 
Other than direct vent 
(Outdoor unit and/or Room Air)  
Other than direct vent 
(Outdoor unit and/or Room Air)  
A 
Clearance above grade, veranda, porch, deck, or 
balcony 
12 in. (30 cm)  12 in. (30 cm) 
B  Clearance to window or door that may be opened  36 in. (91 cm) 
4 ft (1.2 m) below or to side of 
opening; 
1 ft (300 mm) above opening 
C  Clearance to permanently closed window  *  * 
D 
Vertical clearance to ventilated soffit, located above the 
terminal within a horizontal distance of 2 ft (61 cm) 
from the center line of the terminal 
*  * 
E  Clearance to unventilated soffit  *  * 
F  Clearance to outside corner  *  * 
G  Clearance to inside corner  *  * 
H 
Clearance to each side of center line extended above 
meter/regulator assembly 
*  * 
I  Clearance to service regulator vent outlet 
Above a regulator within 3 ft (91 cm) 
horizontally of the vertical center line of 
the regulator vent outlet to a maximum 
vertical distance of 15 ft (4 m) 
* 
J 
Clearance to non-mechanical air supply inlet to 
building or the combustion air inlet to any other 
appliance 
36 in. (91 cm) 
4 ft (1.2 m) below or to side of 
opening; 
1 ft (300 mm) above opening 
K  Clearance to a mechanical air supply inlet  6 ft (1.83 m) 
3 ft (91 cm) above if within 10 ft 
(3 m) horizontally 
L 
Clearance above paved sidewalk or paved driveway 
located on public property 
7 ft (2.13 m) [1]  * 
M  Clearance under veranda, porch, deck, or balcony   12 in. (30 cm) [2]   * 
Clearance to opposite wall is 24 in. (60 cm).  
[1] A vent shall not terminate directly above a sidewalk or paved drive-
way that is located between two single family dwellings and serves 
both dwellings. 
[2] Permitted only if veranda, porch, deck, or balcony is fully open on a 
minimum of two sides beneath the floor. 
  Clearances are in accordance with local installation codes 
and the requirements of the gas supplier. (Dégagement con-
forme aux codes d’installation locaux et aux exigences du 
foumisseur de gaz.) 
AIR SUPPLY INLET 
VENT TERMINAL 
AREA WHERE TERMINAL 
IS NOT PERMITTTED 
X
V