Installation Guide
Polypropylene (PP) Common Venting Installation Instructions 28
Copyright © 2018 Rinnai America Corporation. All Rights Reserved.
Installaon Instrucons
Recommended Spacing of Water Heaters
Spacing of the water heaters is crical for the common
vent system to mounng easily and securely. The
common vent headers are made for 20.5” spacing (center
line to center line) between water heaters. If a dierent
spacing is needed, please contact Rinnai concerning your
applicaon. Rinnai recommends using the Tankless Rack
System (TRS) which is designed for 20.5” spacing. The
engineered system is designed to make installaon simple
and greatly reduces installaon me.
Custom Water Heater Spacing
If common venng with LESS than 20.5” between water heaters:
• The installer assumes all responsibility of following local codes. Inspectors can reject the installaon if the
rang plate cannot be seen for all water heaters.
• The Exhaust Header and 3” Diameter Extension Pieces must be cut appropriately to maintain the required
3° slope.
If common venng with GREATER than 20.5” between water heaters:
• The vent extension and 3” Diameter Extension Pieces must be cut to the appropriate length between to
maintain a 3° slope.
• The length of each addional vent extension must be considered in the maximum allowable vent length.
Exhaust Vent Installaon Procedures:
To maintain a 3° slope, use the following
formula to calculate 3” Diameter Extension
Piece length (L):
(L) = (water heater spacing) X 0.05
Example: if the adjacent water heater is
20.5” away
Length (L) = 20.5” x 0.05 = 1.02”
Example: if the adjacent water heater is 26”
away
Length (L) = 26.0” x 0.05 = 1.30”
20.5”
Vent extension
cut to size
Air Intake
extension
3” Diameter
Extension Piece