Installation Guide
Polypropylene (PP) Common Venting Installation Instructions 5
Copyright © 2018 Rinnai America Corporation. All Rights Reserved.
High Altitude Installations
Tankless water heaters using common venng at altudes over 2,000 Ft will automacally derate according to the
tables below. Use the tables below for calculang your total BTU for mulple tankless water heaters.
• High altude installaons are cered up to 10,200 Ft (3,109 m).
• Reference the respecve Rinnai Tankless Water Heater Installaon and Operaon Manual to set the water
heater up for the altude at which they will be operang.
High Altude Derate
PROPANE (LP GAS)
Number
of Water
Heaters
2,001 -
5,200 Ft
5,201 -
7,700 Ft
7,701 -
10,200 Ft
1 168,000 151,000 120,000
2 332,640 298,980 237,600
3 493,920 443,940 352,800
4 651,840 585,880 465,600
5 806,400 724,800 576,000
6 957,600 860,700 684,000
7 1,105,440 993,580 789,600
8 1,249,920 1,123,440 892,800
NATURAL GAS
Number
of Water
Heaters
2,001 -
5,200 Ft
5,201 -
7,700 Ft
7,701 -
10,200 Ft
1 170,000 153,000 139,000
2 336,600 302,940 275,220
3 499,800 449,820 408,660
4 659,600 593,640 539,320
5 816,000 734,400 667,200
6 969,000 872,100 792,300
7 1,118,600 1,006,740 914,620
8 1,264,800 1,138,320 1,034,160
Must Do
• You must use vent components that are cered
and listed with the water heater model.
• The vent system must vent directly to the outside
of the building and use outside air or room air for
combuson.
• Avoid dips or sags in horizontal vent runs by
installing supports per the vent manufacturer’s
instrucons.
• Support horizontal vent runs a minimum of every
four feet and all vercal vent runs a minimum of
every six feet.
• Venng should be as direct as possible with a
minimum number of pipe ngs.
• Vent connecons must be rmly pressed together
so that the gasketed form an air ght seal.
• Vent components connected to the water heater
must be secured with one self-tapping screw, do
not use any glues or solvents to connect vent
components to the water heater.
• Set the temperature seng on all water heaters
being common vented to the same temperature.
• Unless recovering a tank, Rinnai recommends
electronically connecng with common venng
and where water heaters are in a manifold system.
Refer to the Rinnai installaon and operaon
manual for addional details on electronically
connecng mulple water heaters.
• Refer to the appendix of this manual for Ubbink
vent component assembly and installaon
instrucons.
Information