Installation Sheet
12 Fan Convector Manual
Overheat Switch: The appliance will automacally
shut down when the appliance exceeds a
predetermined temperature. Determine the cause
of overheat and resolve the issue (i.e. if the lters
are determined to be the cause, clean the lters)
and allow heater to cool before turning back on.
Flame Failure Device: The appliance will
automacally shut down if the burner ame is
exnguished.
Oxygen Depleon Sensor: If the oxygen level in
the room drops below a preset limit, this sensor
disables the gas supply to the heater. If this occurs,
turn the heater o and venlate the room before
turning the heater back on. The heater will not
re-ignite unl the room is fully venlated.
Tilt Switch: If the heater is knocked over, the lt
switch will disable the gas supply. The fan will
connue to purge. To re-enable the gas supply,
stand the heater back to its upright posion, turn it
o, and then back on. The lt switch may also
acvate if the heater is jolted or picked up while in
operaon.
Power Failure: The appliance will disable the gas
supply if it loses electrical power. The appliance
can be restarted aer power is restored.
Fuse: The electrical circuits are protected by a fuse.
When the fuse blows, the heater will not operate
unl the fuse is replaced by a qualied service
provider.
Safety Features
Specicaons
FC510 FC824
Gas Connecon 1/2 Inch Male NPT 1/2 Inch Male NPT
Gas Control Electronic Electronic
Burners Ceramic Burner Ceramic Burner
Temperature Control Electronic Thermostat Electronic Thermostat
Ignion System Electronic Spark Ignion Electronic Spark Ignion
Electrical Connecon AC 120V, 60Hz, 19 Was AC 120V, 60Hz, 29 Was
Fuse Size 5 Amps 5 Amps
Fan CFM Low Speed: 67.8/ High Speed: 97.8 Low Speed: 109.5/ High Speed: 215.4
Weight 22.1lb (10kg) 26.5lb (12kg)
Dimensions
Height: 19.4 in (492 mm)
Width: 19.2 in (487 mm)
Depth: 9.6 in (244 mm)
Height: 19 in (482mm)
Width: 24 in (610 mm)
Depth: 9.4 in (239 mm)
FC510 NG LP
Elevaon
0~2000 2001~5200 0~2000 2001~5200
Input
(BTU/h)
Hi 10000 9200 10000 9200
Lo 5500 5500 5600 5600
Hi 1.8 1.8 3.2 3.2
Manifold Pressure (inch
H2O)
Lo 0.64 0.75 1.12 1.31
FC824 NG LP
Elevaon
0~2000 2001~5200 0~2000 2001~5200
Input
(BTU/h)
Hi 24000 22000 22000 20000
Lo 8400 8400 8000 8000
Hi 3.4 3.4 6.3 6.3
Manifold Pressure (inch
H2O)
Lo 0.52 0.61 1.00 1.17