Installation Sheet

12 Fan Convector Manual
Overheat Switch: The appliance will automacally
shut down when the appliance exceeds a
predetermined temperature. Determine the cause
of overheat and resolve the issue (i.e. if the lters
are determined to be the cause, clean the lters)
and allow heater to cool before turning back on.
Flame Failure Device: The appliance will
automacally shut down if the burner ame is
exnguished.
Oxygen Depleon Sensor: If the oxygen level in
the room drops below a preset limit, this sensor
disables the gas supply to the heater. If this occurs,
turn the heater o and venlate the room before
turning the heater back on. The heater will not
re-ignite unl the room is fully venlated.
Tilt Switch: If the heater is knocked over, the lt
switch will disable the gas supply. The fan will
connue to purge. To re-enable the gas supply,
stand the heater back to its upright posion, turn it
o, and then back on. The lt switch may also
acvate if the heater is jolted or picked up while in
operaon.
Power Failure: The appliance will disable the gas
supply if it loses electrical power. The appliance
can be restarted aer power is restored.
Fuse: The electrical circuits are protected by a fuse.
When the fuse blows, the heater will not operate
unl the fuse is replaced by a qualied service
provider.
Safety Features
Specicaons
FC510 FC824
Gas Connecon 1/2 Inch Male NPT 1/2 Inch Male NPT
Gas Control Electronic Electronic
Burners Ceramic Burner Ceramic Burner
Temperature Control Electronic Thermostat Electronic Thermostat
Ignion System Electronic Spark Ignion Electronic Spark Ignion
Electrical Connecon AC 120V, 60Hz, 19 Was AC 120V, 60Hz, 29 Was
Fuse Size 5 Amps 5 Amps
Fan CFM Low Speed: 67.8/ High Speed: 97.8 Low Speed: 109.5/ High Speed: 215.4
Weight 22.1lb (10kg) 26.5lb (12kg)
Dimensions
Height: 19.4 in (492 mm)
Width: 19.2 in (487 mm)
Depth: 9.6 in (244 mm)
Height: 19 in (482mm)
Width: 24 in (610 mm)
Depth: 9.4 in (239 mm)
FC510 NG LP
Elevaon
02000 20015200 02000 20015200
Input
(BTU/h)
Hi 10000 9200 10000 9200
Lo 5500 5500 5600 5600
Hi 1.8 1.8 3.2 3.2
Manifold Pressure (inch
H2O)
Lo 0.64 0.75 1.12 1.31
FC824 NG LP
Elevaon
02000 20015200 02000 20015200
Input
(BTU/h)
Hi 24000 22000 22000 20000
Lo 8400 8400 8000 8000
Hi 3.4 3.4 6.3 6.3
Manifold Pressure (inch
H2O)
Lo 0.52 0.61 1.00 1.17