Installation Sheet

Fan Convector Manual 11
Final Checklist
The heater is not subject to corrosive compounds in the air.
Clearances from the heater are met.
The unit is not installed above 5,200.
The unit has been properly calibrated for the appropriate altude.
A manual gas control valve has been placed in the gas line to the heater.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within limits.
Conrm that the heater is rated for the gas type supplied.
Conrm that the electricity is supplied from a 120 VAC, 60 Hz power source, is in a properly grounded circuit,
and turned on.
Explain to the customer the importance of not blocking the warm air discharge.
Explain to the customer the operaon of the heater, safety guidelines, maintenance, and warranty.
The installaon must conform with local codes or, in the absence of local codes, with the Naonal Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installaon Code, CSA B149.1. If installed in a
manufactured home, the installaon must conform with the Manufactured Home Construcon and Safety
Standard, Title 24 CFR, Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes.
The heater must not be installed in a conned space or unusually ght construcon unless provisions are
provided for adequate combuson and venlaon air.
The appliance is not installed in a bedroom or bathroom.
Leave the enre manual taped to the heater or give the enre manual directly to the consumer.