Appliance Specifications
The following flue manifold sizes are
available for different wall thicknesses:
Name Kit No. fits walls
S Vent Kit FOT-150 3 - 4 1/2 in (75 - 115 mm)
A Vent Kit FOT-151 4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit FOT-152 9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm)
Natural Gas Propane Gas
Minimum supply gas pressure 3.5 in (89 mm) W.C. 8.0 in (203 mm) W.C.
Maximum supply gas pressure 10.5 in (267 mm) W.C. 13.0 in (330 mm) W.C.
BTU/hour input Low 13,200 High 38,400 Low 13,200 High 36,500
BTU/hour output Low 10,560 High 30,720 Low 10,560 High 29,200
Flue Manifolds
Restarts automatically when ignition or combustion
fails.
Clean Heating Forced Flue Type
Easy Operation One-Touch Ignition
Sensible Temperature Control Feature
Programmable Thermostat
Warm Air Outlet at Floor Level (keeps your feet
warm)
Child Lock
Room Temperature Setting Memory
Clean the Air Filter - Indicator Lamp
Energy Saving Economy Setting
Humidifier Tray
Air Flow Directional Louvers
Direct Vent Easily Installed
Proportional Heating Variable Capacity
Hush! Quiet Operation
Modern Design Minimizes Floor Space
Requirements
Dimmer
Fault Code Message Display
Temperature Settings in Fahrenheit or Celsius
Temperature Setting in Timer Operation
Timers 1 and 2
Set back (setting a minimum temperature)
1F°(1C°) increments
Vent A Kit is included with
the appliance.