Installation Sheet

Installation & Servicing Instructions Rinnai E-Series
32
placing air lter on air intake
gure 14c
6.6.3.1 Boiler conversion from concentric to parallel
A. 1. Push the 2 clips slightly outwards
B. 2. Pull the concentric adaptor out of the boiler
3. Press the cover in the connection at the back from inside out
C. 4.Pushthe3"airintakeconnectorintotheconnectionatthebackoftheboiler
5. Pull the rubber seal around the bottom of the exhaust connector
6. Push the exhaust connector in the boiler, in the boiler exhaust pipe until 'CLICK'
7. Push the rubber plug in open position in the O
2
measuring opening and
close the stop.
D. Connect the parallel vent system.
6.6.3.2 Installing air lter
1.Pullthe3"connectionsoutofairintakeoftheboiler
2.Pushtheairlterintotheairintakeontopoftheboiler.Seegure14c.
Theequivalentlengthofthecombustionroomairlteris12ft(3.66m).
boiler conversion from
concentric to parallel
gure 14b
A
OK
C
B