Owner's Manual

Operating instructions Rinnai E-Series
11
Water pressure in the central heating system
The installation will function optimally with a water
pressure of between 16 and 18 PSI (1.1 and 1.3
bar).
If the water pressure drops below 12 PSI, the
display will show a ashing FILL text, alternated
with water pressure indication. During this
message the boiler will remain functioning at a
reduced level. After replenishing the system (see
following chapter) just above 22 PSI the message
FILL will disappear and the boiler will function
normally again.
When the water pressure drops below 10 PSI (0.7
bar), the display will show a ashing FILL text.
The boiler will shut down and will function normally
again after replenishing the system to just above
22 PSI (1.5 bar).
To retreive the water pressure on the display from
the Good reading:
- Press the Step key once briey.
The water pressure will be shown.
Press the Step key briey to return to the Good
reading.
Water pressure is too high (>42 PSI / 3 bar), if
HIGH indication remains continuously visible, the
boiler is taken out of operation. The installation
pressure needs to be decreased by draining water
until the pressure is between 16 and 18 PSI (1.1
and 1.3 bar).
Message ' Water pressure
too low' on your RS100
thermostat.
On the display of the RS100
a low water pressure can
be indicated. For further
information see the relevant
user manual.