Installation Sheet
Installation & Servicing Instructions Rinnai E-Series
67
NOTICE
i
16 Blocks and Errors
16.1 Error indication (short reference)
A detected error is indicated on the display by means of blocking or error messages. A
distinction should be made between these two messages due to the fact that blocking
canbeofatemporarynature,however,errormessagesarexedlockings.Thecontrol
willtryitsutmosttopreventlockingandwilltemporarilyswitchotheunitbyblocking
it. The following is a list of some messages.
Blocks
with a number in the last 2 positions.
Block 01:
Externalsafetycontactcuto
Block 05:
Outdoor sensor not connected
Block 60:
Incorrect parameter setting of the minimum or maximum power.
Block 67:
A Thasbeendetectedbetweenowandreturnsensorwhereastheburnerisnotinoperation.
After the T has disappeared the block will clear.
Block 85:
Thecontrolhasnotdetectedawaterow.Theventingcycleisstarted.
Ifduringthiscyclewaterowisdetected,theventingcycleisendedandtheburnerisreleased.
Error with a number in the last two positions.
Error00: poorame-forming
Error02: noame-forming
Error 04: adjustment or error for voltage interruption
Error 05: adjustment
Error 12: high limit stat
Error18: maximumowtemperatureexceeded
Error 19: maximum return temperature exceeded
Error 28: number of revolutions not reported back from fan
Error 69: no or incorrect display
FUSE: 24V fuse defective
The following pages describes more detailed follow up instructions for solving
blockings, errors and practical circumstances. These instructions are only for
licensed professional.