Specification Sheet

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
C199i (KBD3237FFUDC)
DIMENSIONS
DIM Inches (mm)
A (GAS) 1.6 (40.2)
A (COLD) 2.0 (50.2)
A (HOT) 1.6 (41.2)
A (CONDENSATE
OUTLET)
0.9 (22.4)
B 5.0 (127.2)
C 1.9 (47.8)
D 0.52 (13.3)
B
C
I
J
D
E
F
G
H
K
DIM Inches (mm)
E 2.2 (56.3)
F 2.3 (58.3)
G 5.0 (127.2)
H 2.0 (50)
I 3.0 (76)
J 7.1 (179)
K 18.3 (466)
Heat exchanger: 5years*, All other parts: 5 years*; Labor: 1 year;
(* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in
series with a circulation system and all circulating water flows through the water heater, and where an
aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.)
Refer to the manual for complete warranty information.
Limited
Warranty
WEIGHT: 61.7 lb (28 kg)
MC-91-2US (included)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse
Top of heater - 6 inches (152mm)
Front of heater - 6 inches *(152mm)
Sides of heater - 2 inches (51mm)
Top of heater - 2 inches (51mm)
Front of heater - 6 inches *(152.mm)
Sides of heater - 1/2 inches (13mm)
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar)
Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Natural Gas: high fire 3.0” W.C. (7.5mbar) low fire 0.42” W.C. (1.1mbar)
Propane Gas: high fire 3.5” W.C. (8.7mbar) low fire 0.47” W.C. (1.2mbar)
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm
NOx emission levels
g
-Ubbink Polypropylene Concentric Vent
-Twin Pipe PVC/CPVC (3” and 4” configurations)
-Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adapter);
-Common Vent Solutions
-Room Air (Room air can be used only in commercial common vent applications where
the exhaust terminates vertically)
See installation and operation manual for more details.
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches (305mm)
From vent pipe - 0 inches
Back of heater - 0 inches
Bottom of heater - 12 inches (305mm)
From vent pipe - 0 inches
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
* 24 inches (610mm) required for service
Clearances from Non-combustibles
* 24 inches (610mm) required for service
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Venting
ø 5.5 (140.2)
31.2 (791.3)
2.02 (51.3)
20.6 (523.3)
2.8 (70.1)
10.1 (257.7)
28.5 (723.3)
25.7 (654)
8.7 (222)
A
1.2 (31.2)
2.9 (74.6)
5.9 (150)