Owner's Manual
C199 Manual 51
* Minimum ow may vary slightly depending on the temperature seng and the inlet water temperature.
Minimum acvaon ow is 0.4 GPM (1.5 L/min).
Our products are connually being updated and improved; therefore, specicaons are subject to change without prior noce.
The maximum inlet gas pressure must not exceed the value specied by the manufacturer. The minimum value listed is for the
purpose of input adjustment.
C199i C199e
Minimum Gas Consumpon Btu/h 15,200
Maximum Gas Consumpon Btu/h 199,000 199,000
Hot water capacity (Min - Max) *
0.26 - 9.8 GPM
(1.0 - 32 L/min)
0.26 - 9.8 GPM
(1.0 - 32 L/min)
Temperature Seng (no controller) 120° F (49° C) or 140° F (60° C)
Maximum Temp Seng Selectable at 120° F (49° C), at 140° F (60° C), or at 185° F (85° C)
Minimum Temperature Seng 98° F (37° C)
Weight 61.7 lb (28 kg)
Noise level 41 dB 52 dB
Electrical Data
Normal 75 W 71 W
Standby 2 W
An-frost Protecon 146 W 168 W
Max Current Without recirculaon pump: 4 A
Fuse 10 A
By-Pass Control Electronic
Gas Supply Pressure
Natural Gas 4.0 - 10.5 inch W.C.
Propane 8.0 - 13.5 inch W.C.
Type of Appliance
Condensing, Tankless, Temperature controlled connuous ow gas
hot water system
Connecons
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water
Outlet: 3/4" MNPT
Ignion System Direct Electronic Ignion
Electric Connecons
Appliance: AC 120 Volts, 60Hz.
Temperature Controller: DC 12 Volts (Digital)
Water Temperature Control Simulaon Feed forward and Feedback
Water Supply Pressure
Minimum Water Pressure: 50 PSI (Recommended 60-80 PSI for
maximum performance)
Maximum Water Supply Pressure 150 PSI
Remote Control Cable Non-Polarized Two Core Cable (Minimum 22 AWG)
Energy Star Qualied Yes
Complies with South Coast Air Quality Management District 14 ng/
J or 20 ppm NOx emission levels
Yes