Owner's Manual
C199 Manual 39
Vent Components and Assigned Equivalent Lengths:
The following ngs and accessories (by others) are cered for use with the abovemenoned condensing products:
IPEX (Purchased
separately )
196006 /197009
(3 Inch)
196021 /197021
(4 Inch)
(System 636)
PVC/CPVC- FGV
Concentric Vent Kit w/
vent screen
20
IPEX (Purchased
separately )
196985
(3 Inch)
196986
(4 Inch)
(System 636)
Low Prole
Terminaon Kit
5
Field Supplied
PVC/CPVC Sch. 40
Fings or Ap-
proved Equal
Comply with
CAN/CGA
B149.1 &
ULC-S636
3” and 4” SCH 40 (Solid
Core) PVC/CPVC TEE
w/ vent screen
5
Field Supplied
PVC/CPVC Sch. 40
Fings or Ap-
proved Equal
Comply with
CAN/CGA
B149.1 & ULC-
S636
3” and 4” SCH 40 (Solid
Core) PVC/CPVC 90° EL
w/ vent screen
5
Field Supplied
PVC/CPVC Sch. 40
Fings or Ap-
proved Equal
Comply with
CAN/CGA
B149.1 & ULC-
S636
3” and 4” SCH 40 (Solid
Core) PVC/CPVC 45° EL
w/ vent screen
2.5
IPEX (Purchased
separately )
196051
(3 Inch)
196052
(4 Inch)
Fricon t vent screen
(3” and 4”)
0
Field Supplied
PVC/CPVC Sch. 40
Fings or
Approved Equal
Comply with
CAN/CGA
B149.1 &
ULC-S636
3” and 4” SCH 40 (Solid
Core) PVC/CPVC
Snorkel vent w/
vent screen
(2X90°
or
2X90° EL + 1X45° EL)
15
Vent screens are not ULC S636 Cered.
Fricon t vent screens inside terminaon ng are used to avoid debris and/or small animals from entering vent.
Primer shall be used when installing System 636® and other PVC/CPVC products at temperatures below 32
O
F (0
O
C).
Primer is required in some jurisdicons regardless of temperature, verify with your local authority having jurisdicon.
Use only System 636 cements and primers; substung other cements and primers will void IPEX’s cercaon and
warranty; (see OEM’s literature).
For Schedule 40 PVC/CPVC, any glue and primer approved by your local authority having jurisdicon may be substuted.
Parts Informaon (connued)