Owner's Manual

34 C199 Manual
The following informaon should be used in conjuncon
with the IPEX System 636 Installaon Guide:
Terminaon kits are to be tested and cered for use
with the brand of pipe-ng-cement system that is to
be ulized in the applicaon. The IPEX Low Prole
terminaon is fully cered for use with IPEX product
only.
System 636 PVC Low Prole Vent kits are rated to 65°C
maximum and are made from cered compound.
All terminaon kits must be located and installed in
accordance with these instrucons, local building code,
and CSA B149.1 Natural Gas and Propane Installaon
Code.
All exhaust vents and air inlets must terminate at the same
height to avoid property damage, personal injury, or death.

Cered PVC/CPVC Vent Terminaon Opons (connued)

1. Once a proper locaon has been determined, cut 2
appropriately sized holes in the wall to accommodate
the pipe. (Reference the Low Prole Terminaon
Kit-Dimensions table below)
2. Slide intake and exhaust pipes through the holes.
Secure (using solvent cement) both pipes to the base
of the vent terminaon kit. (Be sure to follow
guidelines for solvent cemenng as described in the
System 696 Installaon Guide)
3. Use the supplied screws and anchors to secure the
base to the wall. (a drilled 3/16” hole, 1-3/16” deep
will be needed for the anchors.) Use the base as a
template to locate the anchor hole.
4. Using the supplied screws, secure the Cap to the Base.
5. Upon securing the vent terminaon and pipes, seal the
wall penetraons (from the interior) using a PVC
compable sealant material.
Item # Descripon Pipe Outside
Diameter
Hole Spacing
196985 3” Flush Mount 3.5” 5.6”
196986 4” Flush Mount 4.5” 5.6”
-
Qty Item Descripon
1 Base (Two Holes)
1 Cap (One Hole)
8 Stainless Steel Screws
4 Plasc Anchors

Air Piping
Vent Piping
Vent Base
Vent Cap
Vent
Air
Vent / Air
Terminaon
12” Min Between Edge of Air
Inlet and Adjacent Vent Outlet

From Water Heater Vent
Pipe Connecon
To Water Heater Intake Air
Connecon
12” min
Vent / Air
Terminaon
Orientaons
Grade or
Snow Line