SDS

Guangzhou Great Power Energy & Technology Co., Ltd
Safety Data Sheet
Date of Issue: 22-Jan-2015 File No.: GR-SDS-2015-05
Page 2 of 7
This sheet is provided as technical information only. The information and recommendations set forth are made in good faith and
believed to be accurate as of the date of preparation. Guangzhou Great Power Energy & Technology Co., Ltd make no warranty,
expressed or implied, with respect to this information and disclaims all liabilities from reliance on it.
Contact with battery electrolyte may cause burns. Eye damage is possible.
Inhalation
Inhalation of a large number of vapors or fumes released due to heat may cause respiratory.
Ingestion
Ingestion of battery contents may cause mouth, throat and intestinal burns and damage.
Unknown Toxicity
No information available.
3. Composition/ Information on Ingredients
Chemical Name Molecular formula CAS No. Weigh%
Lithium Cobalt Oxide LiCoO2 12190-79-3
3035
Graphite C 7782-42-5
1520
Polypropylene C3H6 9003-07-0
24
Copper Cu 7440-50-8
58
Aluminum Al 7429-90-5
2535
Lithium hexafluorophosphate
LiPF6
21324-40-3
13
Ethylene Carbonate
C3H4O3
96-49-1
3
4
Ethylmethyl Carbonate
C4H8O3
623-53-0
3
4
Dimethyl Carbonate
C3H6O3
616-38-6
3
4
4. First Aid Measures
General Advice
First aid is Applicable only in the case of cell rupture.
Skin Contact:
Washing immediately with plenty of water and soap for at least 15 minutes. In the case of skin irritation or
allergic reaction see a physician.
Eye contact:
If symptoms persist, call a physician. Rinse immediately with plenty of water, also under the eyelids, for at least
15 minutes. Keep eye wide open while rinsing. Remove contact lenses, if present and easy to do. Continue
rinsing. Do not rub affected area.
Inhalation of Vented Gas:
Remove to fresh air. If symptoms persist, call a physician. Get medical attention immediately if symptoms
occur.
Ingestion:
Do not induce vomiting. Rinse mouth immediately and drink plenty of water. Call a physician or poison control
center immediately.
Most important symptoms and effects, both acute and delayed
Contact with internal components may cause allergic skin sensitizations (rash) and irritate eyes,
nose, throat, respiratory system. Cobalt and cobalt compounds are considered to be possible
human carcinogen(s).
Indication of any immediate medical attention and special treatment needed
No information available
5. Fire Fighting Measures