10. Turn Front-to-Back Alignment Screw until there is a 1/16” (1.5mm) gap between
the front edge of the disc and the raised edge of the disc retainer.
Disc Retainer Gap Distance
11. Once the printer is aligned, rotate the leadscrew to raise the lift arm.
12. Pull the disc down from the gripper fingers.
13. Press and hold
the operator button to exit diagnostic test 4.
14. Press the operator button fourteen times and hold on the last press to exit
diagnostics.
15. Press the operator button once more to close the print drawer.