Technical data

10. FAULT FINDING AND SOLUTIONS
PROBLEM
The fire is burning with a weak, orange
flame. Pellets are collecting in the fire
grate, window is covered in soot.
CAUSE:
Inadequate combustion air.
POSSIBLE SOLUTIONS:
Ensue that the combustion pan is sitting
in the combustion pan holder correctly.
Combustion pan must sit tight on the
combustion pan holder.
Remove ash or clinker that could be
blocking the air inlet openings from the
fire grate. If possible change to a better
pellet quality.
Check if the flue gas extraction pipe is
blocked with ash (see „Maintenance“
page).
Check if the air inlet channel or smoke
tube is blocked.
Check door seal.
Clean fan wheel.
Have fire serviced by authorised dealer
(adjust control and flue gas fan).
PROBLEM
Fire goes out or switches itself off auto-
matically.
CAUSE(S):
Pellet container is empty.
Pellets are not being fed in.
Thermal switch (upper temperature
limit) was triggered.
Door seal not tight or not closed tightly.
Poor pellet quality.
Pellet feed rate too low.
Thermal switch (lower temperature limit)
was triggered.
POSSIBLE SOLUTIONS:
Fill up pellet container.
See following problem „pellets are not
being fed in“.
Leave fire to cool down for an hour and
then light again.
See „routine maintenance“.
Only use pellet brands recommended.
Have the fuel control set by your dealer.
PROBLEM
Pellets are not fed in.
CAUSE(S):
Pellet container is empty.
Conveyor drive or control board is faulty.
Worm is blocked (objects, wood etc.).
POSSIBLE SOLUTIONS:
Check container content. If necessary fill
up with pellets.
Have the dealer check the fault and
replace parts if necessary.
Clean pellet container and worm
conveyor.
PROBLEM
Fire runs for 21 minutes and switches
off.
CAUSE(S):
Exhaust gas has not reached the required
temperature.
Lower temperature limit value switch
possibly needs to be replaced.
Line to lower or upper excess tempera-
ture switch is either loose or broken.
Control is faulty.
POSSIBLE SOLUTIONS:
Start fire again if necessary.
Have service technician replace low
temperature switch and check control.
Inspect cabling, see block diagramm
(Fig. 8). Check that there is a good
connection between the lines and ends
(terminals).
Caution: Remove the plug!
22
ENGLISH