Technical data
ENGLISH
After the „LA“ value has been confirmed
using „ENTER“, the „RZ“ (Cleaning Cycle)
value is shown with the value in minutes
(lower display). The value can be altered in
increments of one minute using the +/-
keys. (When the prescribed fuel is used, we
recommend that the cleaning run is carried
out every 60 minutes). The value for the
„RZ“ is confirmed using „ENTER“ and selec-
ting „MENU“ the display will show the time
programming „ZH“.
Time programming:
The top display shows „ZH“ (internal clock
hour memory) and the bottom display
shows the value in hours. The +/- key is
used to alter the value, confirm using
„ENTER“ and „ZM“ (internal clock minute
memory) then appears. Alter the minute
value using +/-, pressing „ENTER“ displays
„WT“ (weekday, MO=1, DI=1 -› SO=7), +/-
alters the value. Selecting „MENU“ displays
„RI“.
Tele-Control
(optional telephone triggering):
This function is not part of the standard
display and can be retrofitted if required.
The relevant additional device functions
and the programming of the system values
are included in the retrofitting kit.
Standby-Mode:
The fire is switched off in this operating
mode but remains active to receive tele-
phone triggering. The display shows „SB“.
Starting the fire for the first time
General remarks
➧ Check that the pellet container is full and
the combustion chamber is clean and
free from ash.
After filling the storage tank and plugging
the fire in, the start programme is carried
out by pressing the „ON/OFF“ button on
the internal control unit. The fire carries
out the „Manual operating mode“ (see
Manual Operation, page 15).
You can now select the operating modes as
per the Possible Operating Ranges Item
(Page 14) in accordance with your require-
ments.
Stopping the fire
Switching off from „Manual Operation“
If the „ON/OFF“ button is pushed during
operation, then all functions will continue
to run (without the conveying worm), so
long until the fire has cooled down suffi-
ciently and the following alternating infor-
mation appears on the display (in an appro-
ximately 2 second cycle):
a) ON manual operation with xx%
heating output
b) VZ delay phase of xxx seconds
c) CL clear (cleaning phase) of xxx
seconds
d) NL after running of xxx seconds
(The whole switch off procedure will take
approximately 7 seconds)
After the switch off programme has finished
the display goes out. A new start then takes
place by pushing the „ON/Off“ button.
CAUTION! The combustion chamber door must
be closed during the ignition procedure. The
electric ignition will not work if the combustion
chamber door is open.
When the pellet container is opened for the
first time, no pellets are transported into the
fire pan. You can put a handful of pellets in
the combustion pan to prevent the fire from
restarting again.
16