Technical data

GENERAL
ATTENTION! Only carry out any work on the
fire when the mains plug has been removed.
13
6. FITTING OPTIONS
When fitting do not allow any items (screws
etc.) to drop into the fuel container - they
can block the conveyor screw and damage
the fire.
The fire must be switched off and have cooled
down before work can be carried out.
ENGLISH
FITTING THE STEEL OR CERAMIC
FRONT CLADDING, CERAMIC LID
WITH INSERT
(Fig. 6)
1. Open both corner posts (Fig. 6, Part 45
and 48) by slackening the hexagonal
bolts at the top on the front corner post
bracket.
2. Hang the bottom front cladding (Fig. 6,
Part 46) in the edges of the cleaning
door. The bottom brackets centre the
front cladding in the centre of the fire.
3. Upper front cladding: First remove both
hexagonal screws in the front of the
frame (next to the corner post fixing
screws). Now hang the upper front clad-
ding (Fig. 6, Part 47) in the recess in the
frame and fix it using the previously
removed hexagonal screws.
4. Now carefully let the corner post snap
into the bottom spring steel clip and fix it
in the upper area again using the hexago-
nal screws as per Item 1.
5. Open the pellet container lid (Fig. 6, Part
40). Align the ceramic lid on the pellet
fire using the insert (Fig. 6, Part 50).
The round recesses in the bottom must
be positioned on the outer hexagonal
screws in the front frame.
CAUTION! The corner posts have been snapped
in a spring steel clip at the bottom - open by
pulling accordingly.
FITTING THE CONVECTION FAN
(OPTIONAL)
(Fig. 6)
Remove the rear side panels (Fig. 6, Part 42)
on the left and right by removing the hexa-
gonal screws at the top front and rear on
the rear panel. Pay attention to the feed for
the internal control unit when doing this.
Nut
Picture 1
Using the 2 nuts supplied fasten the con-
vection fan on the screws provided in the
combustion chamber rear panel (Fig. 1), by
inserting the washer under the nut.
Nut
Picture 2
Convection fan plug
Lay the power line in the mounts on the
control board casing and insert the 2-pole
plug in Position III.
Now fit the rear side panels on the left and
right side again.
CAUTION! The convection fan must only be
fitted by an authorised specialist.