Technical data

|23
EN
22
key display description
INFO Access to information menu, various system statuses, temperatures and operating information can be called up here.
IN INFORMATION INPUTS
FLAME
319
Display of current flame temperature.
MENU
ROOM
22
Display of current room temperature.
MENU
R-MAX Display menu maximum duration without connection to wireless room sensor
MENU
EXTON Display of status of external release. (ON or OFF)
MENU
DOOR ON Display of the status of door contact. (ON or OFF)
MENU
STB ON Display of the status of safety temperature limiter. (ON or OFF)
MENU
GRID ON Status display for the mudhole door contact (ON or OFF)
MENU
CSENS Display of the current C-sensor value
MENU
IN INFORMATION INPUTS
MENU
OUT INFORMATION OUTPUTS
AUGER OFF Display of operating status of screw motor. (ON or OFF)
MENU
AUGER 00 Display of actual push-in rate.
MENU
FAN ON Display of operating status of flue gas blower. (ON or OFF)
MENU
FAN 00 Display of speed of flue gas blower.
MENU
C-FAN OFF Display of the operating status of the optional cross-flow fan. (ON or OFF)
MENU
C-FAN 00 Display of the speed of the cross-flow fan.
MENU
IGNIT OFF Display of operating status of ignition element. (ON or OFF)
MENU
GRID OFF Display of the operating status of the mudhole door motor. (ON or OFF)
MENU
OUT INFORMATION OUTPUTS
MENU
PAR INFORMATION PARAMETER
RUN - T
63
Display of previous total operating hours.
MENU
RUNKG
245
Display of total pellet amount supplied up to present.
MENU
SERKG
245
Display of conveyed pellet amount since the last cleaning and maintenance.
MENU
TPO 0124 Display of current software version loaded on control board. (Scrolling text)
MENU
PMSM-VER 003 Display of the current software version of the auxiliary board. (Scrolling text)
MENU
U-VER 13 Display of current software version loaded on control unit.
MENU
TEL S 12 Coding software
MENU
TEL H 1024 Coding hardware
MENU
PAR Repeated pressing returns you to the main menu level.