Instructions
RIGOL         Chapter 4 Functions of the Front Panel of EMI 
4-44              RSA3000E User Guide  
Trace 
Selected Trace 
Trace1 
Trace Type 
Clear Write 
Trace Det 
Pos Peak 
Detector Auto 
On 
Trace Update 
On 
Trace Display 
On 
Mode Setup 
Global CF 
Off, 515 MHz 
EMC Standard 
CISPR 
Select Meter 
Meter 1 
Meter 
On 
Detector 
Pos Peak 
Limit  
Off, 80 dBuV 
Dwell Time 
10 ms 
Peak Hold Type 
Infinite 
Adjust Time 
2 s 
Couple to Signal 
Off 
Couple to Marker  
Off 
Meas Setup 
Frequency Scan 
Avg Number 
1 
Avg Type 
Scalar 
Avg Auto 
Auto 
Test Limits 
Off 
Select Limit 
Limit 1 
Limit State 
Off 
Test Trace 
Trace1 
X to CF 
Fixed 
Y to Ref 
Fixed 
Margin 
Off, 0 dB 
Freq Interpolation 
Lin 
Frequency 
0 Hz 
Amplitude 
106.99 dBuV 
Build From 
Trace1 
Copy From 
Limit 1 
X Offset 
0 Hz 
Y Offset 
0 dB 
Select Signal 
1 
Delete 
Selected 
Sort Signals 
By Freq 
Sort Order 
ASC 
Auto Sort 
On 
Search Criteria 
Peak Criteria 