Instructions

RIGOL Chapter 3 Command System for EMI Mode
3-26 RSA3000E Programming Guide
Return Format
The query returns 0 or 1.
Example
The following command enables the peak threshold line.
:CALCulate:MARker:PEAK:SEARch:THReshold:LINe ON
or :CALCulate:MARker:PEAK:SEARch:THReshold:LINe 1
The following query returns 1.
:CALCulate:MARker:PEAK:SEARch:THReshold:LINe?
:CALCulate:MARKer<n>:LINes[:STATe]
Syntax
:CALCulate:MARKer<n>:LINes[:STATe] OFF|ON|0|1
:CALCulate:MARKer<n>:LINes[:STATe]?
Description
Enables or disables the marker line of the specified marker.
Queries the status for the marker line of the specified marker.
Parameter
Name
Type
Range
Default
<n>
Discrete
1|2|3|4|5|6|7|8
--
--
Bool
OFF|ON|0|1
OFF|0
Remarks
If the marker is not visible in the selected area, enable the marker line function to extend the marker line to
the display area for better observation.
Return Format
The query returns 0 or 1.
Example
The following command enables the marker line of Marker 1.
:CALCulate:MARKer1:LINes:STATe ON or :CALCulate:MARKer1:LINes:STATe 1
The following query returns 1.
:CALCulate:MARKer1:LINes:STATe?
:CALCulate:MARKer<n>:STATe
Syntax
:CALCulate:MARKer<n>:STATe OFF|ON|0|1
:CALCulate:MARKer<n>:STATe?
Description
Enables or disables the specified marker.
Queries the status of the specified marker.