Instructions
RIGOL  Chapter 4 Command System for VSA Mode 
4-42  RSA3000E Programming Guide 
[:SENSe]:CORRection:SA[:RF]:GAIN 
Syntax 
[:SENSe]:CORRection:SA[:RF]:GAIN <rel_ampl> 
[:SENSe]:CORRection:SA[:RF]:GAIN? 
Description
Sets the external gain. 
Queries the external gain. 
Parameter 
Name 
Type 
Range 
Default 
<rel_ampl> 
Consecutive Real Number 
-120 dB to 120 dB 
0 dB 
Return Format
The query returns the external gain value in scientific notation. The unit is dB. 
Example
The following command sets the external gain value to 20 dB.  
:SENSe:CORRection:SA:RF:GAIN 20  
The following query returns 2.000000000e+01.  
:SENSe:CORRection:SA:RF:GAIN? 
[:SENSe]:DDEMod:ALPHa 
Syntax 
[:SENSe]:DDEMod:ALPHa <real> 
[:SENSe]:DDEMod:ALPHa? 
Description
Sets the roll-off factor of the raised cosine or the BT value of the Gaussian filter. 
Queries the roll-off factor of the raised cosine or the BT value of the Gaussian filter. 
Parameter 
Name 
Type 
Range 
Default 
<real> 
Consecutive Real Number 
0.05 to 100 
0.22 
Return Format
The query returns the roll-off factor or the BT value in scientific notation. 
Example
The following command sets the roll-off factor of the raised cosine to 0.22.  
:SENSe:DDEMod:ALPHa 0.22 
The following query returns 2.200000000e-01.  
:SENSe:DDEMod:ALPHa? 










