Instructions
RIGOL  Chapter 3 Command System for EMI Mode 
3-64  RSA3000E Programming Guide 
When the EMC measurement standard is "None", this command is invalid. When the EMC measurement 
standard is "CISPR", select the Auto RBW mode by default. 
Return Format
The query returns 0 or 1. 
Example
The following command enables the auto setting mode of RBW.  
:SENSe:BANDwidth:RESolution:AUTO ON or :SENSe:BANDwidth:RESolution:AUTO 1 
:SENSe:BWIDth:RESolution:AUTO ON or :SENSe:BWIDth:RESolution:AUTO 1 
The following query returns 1.  
:SENSe:BANDwidth:RESolution:AUTO? 
:SENSe:BWIDth:RESolution:AUTO? 
[:SENSe]:CORRection:CSET:ALL:DELete 
Syntax 
[:SENSe]:CORRection:CSET:ALL:DELete 
Description 
Deletes all the amplitude correction data. 
[:SENSe]:CORRection:CSET:ALL[:STATe] 
Syntax 
[:SENSe]:CORRection:CSET:ALL[:STATe] OFF|ON|0|1 
[:SENSe]:CORRection:CSET:ALL[:STATe]? 
Description
Enables or disables all the amplitude correction functions. 
Queries the status of the amplitude correction function. 
Parameter
Name 
Type 
Range 
Default 
-- 
Bool 
OFF|ON|0|1 
OFF|0 
Remarks 
When the function is disabled, settings for all the corrections are disabled. 
When the function is enabled, settings for all the corrections are enabled, and the "Antenna" correction is 
enabled by default. 
To enable or disable settings for each correction, refer to the 
[:SENSe]:CORRection:CSET<n>[:STATe] 
command. 
Return Format
The query returns 0 or 1. 
Example
The following command enables the amplitude correction function. 
:SENSe:CORRection:CSET:ALL:STATe ON or :SENSe:CORRection:CSET:ALL:STATe 1 
The following query returns 1. 
:SENSe:CORRection:CSET:ALL:STATe? 