Instructions
Chapter 2 Command Systems for GPSA and RTSA Modes  RIGOL 
RSA3000E Programming Guide  2-179 
Return Format 
The query returns the output amplitude in scientific notation. 
Example
The following command sets the output amplitude to -10 dB.  
:SOURce:EXTernal:POWer:LEVel:IMMediate:AMPLitude -10 
The following query returns -1.000000000e+01.   
:SOURce:EXTernal:POWer:LEVel:IMMediate:AMPLitude? 
:SOURce:TRACe:REFerence:STATe 
Syntax 
:SOURce:TRACe:REFerence:STATe OFF|ON|0|1   
:SOURce:TRACe:REFerence:STATe?
Description
Sets whether to display the reference trace of normalization.  
Queries whether to display the reference trace of normalization.
Parameter
Name 
Type 
Range 
Default 
—— 
Bool 
OFF|ON|0|1 
OFF|0 
Remarks
This command is only valid when the tracking generator function is enabled. 
Return Format
The query returns 0 or 1. 
Example
The following command enables the reference trace.  
:SOURce:TRACe:REF:STATe ON or :SOURce:TRACe:REF:STATe 1 
The following query returns 1.   
:SOURce:TRACe:REF:STATe? 
:SOURce:TRACe:STORref 
Syntax
:SOURce:TRACe:STORref 
Description
Saves the reference trace of normalization. 
Remarks 
This command is only valid when the tracking generator function is enabled. 