Instructions
RIGOL  Chapter 2 Command Systems for GPSA and RTSA Modes 
2-162  RSA3000E Programming Guide 
Example 
The following command sets the maximum power of the input mixer to -20 dBm.  
:SENSe:POWer:RF:MIXer:RANGe:UPPer -20 
The following query returns -2.000000000e+01.   
:SENSe:POWer:RF:MIXer:RANGe:UPPer? 
[:SENSe]:SIGCapture:2FSK:AMPDown 
Syntax 
[:SENSe]:SIGCapture:2FSK:AMPDown <ample> 
[:SENSe]:SIGCapture:2FSK:AMPDown? 
Description
Sets the lower limit of the amplitude of 2FSK signal.  
Queries the lower limit of the amplitude of 2FSK signal. 
Parameter
Name 
Type 
Range 
Default 
<ample> 
Consecutive Real Number 
-400 dBm to amplitude upper limit 
-100 dBm 
Remarks 
This command is only available for RTSA mode and valid when the SSC function is enabled. 
Return Format
The query returns the amplitude lower limit in scientific notation. 
Example
The following command sets the amplitude lower limit to -20 dBm.  
:SENSe:SIGCapture:2FSK:AMPDown -20 
The following query returns -2.000000000e+01.   
:SENSe:SIGCapture:2FSK:AMPDown? 
[:SENSe]:SIGCapture:2FSK:AMPUp 
Syntax 
[:SENSe]:SIGCapture:2FSK:AMPUp <ample> 
[:SENSe]:SIGCapture:2FSK:AMPUp? 
Description
Sets the upper limit of the amplitude of 2FSK signal.   
Queries the upper limit of the amplitude of 2FSK signal. 
Parameter
Name 
Type 
Range 
Default 
<ample>   
Consecutive Real Number 
-100 dBm to 320 dBm 
-10 dBm 
Remarks 
This command is only available for RTSA mode and valid when the SSC function is enabled. 