Instructions
Chapter 2 Functions of the Front Panel of GPSA  RIGOL 
RSA3000E User Guide  2-83 
6.  Search Mode 
Sets the peak search condition: maximum value on the trace or the parameter 
that meets the search criteria. 
  The available options are Max and Para. If "Max" is selected, the system 
searches for the maximum value on the trace. This setting applies only to 
the peak search executed by pressing Peak. Other searches such as Next 
Peak, Next Peak Right, and Next Peak Left are all searched based on "Para". 
  If "Para" is selected, the system searches for the peak that meets the 
search criteria on the trace. 
Peak Table 
Turns on or off the peak table. By default, it is Off. 
When the peak table is turned on, the display is split into a measurement window 
and a peak table display window. The peak table will be displayed at the lower 
section of the screen, displaying the searched parameters (frequency and amplitude) 
that meet the criteria. You can use the externally connected mouse to click and drag 
the slide bar, use the scroll wheel in the middle of the mouse, use the touch screen 
gestures, press the Up/Down arrow keys and the corresponding keyboard shortcut 
keys to page up and down the peak table. 
The marker table currently opened can be saved to the internal or external memory 
of the analyzer, and you can recall it at any time if you need. Press Save to save it 
according to descriptions in "Save". 