Data Sheet
25
RIGOL
Counter
Resolution max. 6 bits, user-defined
Max. Frequency max. bandwidth of the analog channel
Totalizer
48-bit totalizer
Edge count the number of the rising edges
Time Reference Internal Reference
Customization for Quick Key
Customization for Quick Key
Quick Screenshot
Quickly save the screen image to the specified path based on the current image storage menu
settings
Quick Waveform Save
Quickly save the screen or memory waveforms to the specified path based on the current
waveform storage menu settings
Quick Save Settings Quickly save the setup file to the specified path based on the current setup storage menu settings
Quick All Measurement Display all the prompt message windows for all the measurement of the waveforms.
Quick Reset of Statistics
Quickly reset all the measurement statistics data and measurement counts
Quickly reset all the statistics information in PassFail function
Command Set
Command Set
Common Commands Support IEEE488.2 Standard
Error Message Definition Error messages
Support Status Report Mechanism Status reporting
Support Syn Mechanism Synchronization
Display
Display
LCD 10.1-inch capacitive multi-touch screen/gesture enabled operation
Resolution 1024×600 (Screen Region)
Graticule (10 vertical divisions) x (8 horizontal divisions)
Persistence Off, Infinite, variable persistence (100 ms to 10 s)
Brightness 256 intensity levels (LCD,HDMI)
I/O
I/O
USB 2.0 Hi-speed Host Port 4 (3 on the front panel and 1 on the rear panel)
USB 2.0 Hi-speed Device Port 1 on the rear panel, compatible with USB Test and Measurement Class (USBTMC)
LAN 1 on the rear panel, 10/100/1000-port, supporting LXI-C
GPIB GPIB-USB adapter (option)
Web Remote Control
Support VNC Web interface (input the IP address of the oscilloscope into the Web browser to
display the operation interface of the oscilloscope)
Aux Output
BNC output on the rear panel
Vo (H)≥2.5 V open circuit, ≥1.0 V 50 Ω to GND
Vo (L)≤0.7 V to load ≤4 mA; ≤0.25 V 50 Ω to GND
Trig Out Output a pulse signal when the oscilloscope is triggered
Pass/Fail
Output a pulse signal when a pass/fail event occurs. Support user-defined pulse polarity and pulse
time (100 ns ~ 10 ms)
HDMI video output 1 on the rear panel, HDMI 1.4b, A plug. used to connect to an external monitor or projector
Probe Compensation Output 1 kHz, 3 Vpp square waveform
Power Supply
Power Supply
Power Voltage 100 V-240 V, 45 Hz-440 Hz
Power Max. 200 W (connect to various interfaces, USB, and active probes)
Fuse 3.15 A, T degree, 250 V