Data Sheet
25
RIGOL
Command Set
Command Set
Common Commands Support IEEE488.2 Standard
Error Message Definition Error messages
Support Status Report Mechanism Status reporting
Support Syn Mechanism Synchronization
Display
Display
LCD 9-inch capacitive multi-touch screen/gesture enabled operation
Resolution 1024×600 (Screen Region)
Graticule (10 vertical divisions) x (8 horizontal divisions)
Persistence Off, Infinite, variable persistence (100 ms to 10 s)
Brightness 256 intensity levels (LCD,HDMI)
I/O
I/O
USB 2.0 Hi-speed Host Port 1 on the front panel
USB 2.0 Hi-speed Device Port 1 on the rear panel, compatible with USB Test and Measurement Class (USBTMC)
LAN 1 on the rear panel, 10/100/1000-port, supporting LXI-C
GPIB GPIB-USB adapter (option)
Web Remote Control
Support VNC Web interface (input the IP address of the oscilloscope into the Web browser to
display the operation interface of the oscilloscope)
Aux Out
BNC output on the rear panel.
Vo (H)≥2.5 V open circuit, ≥1.0 V 50 Ω to GND
Vo (L)≤0.7 V to load ≤4 mA; ≤0.25 V 50 Ω to GND
Trigger Output Output a pulse signal when the oscilloscope is triggered.
Pass/Fail
Output a pulse signal when a pass/fail event occurs. Supports user-
defined pulse polarity and pulse time (100 ns~10 ms).
HDMI video output 1 on the rear panel, HDMI 1.4b, A plug. used to connect to an external monitor or projector
Probe Compensation Output 1 kHz, 3 Vpp square waveform
Power
Power Supply
Power Voltage 100 V-240 V, 45 Hz-440 Hz
Power Max. 75 W (connect to various interfaces, USB)
Fuse 4 A, T degree, 250 V
Bode
Bode
Start Frequency 10 Hz to 25 MHz
Stop Frequency 100 Hz to 25 MHz
Points/Decade 10 to 300
Output Amplitude HighZ: 20 mV to 5 V; 50Ω: 10 mV to 2.5 V
Environment
Environmental Stress
Temperature Range
Operating 0℃~+50℃
Non-operating -30℃~+70℃
Humidity Range
Operating
Below +30℃: ≤90% RH (without condensation)
+30℃ to +40℃, ≤75% RH (without condensation)
+40℃ to +50℃, ≤45% RH (without condensation)
Non-operating Below 65℃: ≤90% RH (without condensation)
Altitude
Operating Below 3,000
Non-operating Below 15,000