Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 3 To Set the Horizontal System
3-2 MSO5000-E User Guide
To Adjust the Horizontal Timebase
Horizontal timebase, also called the horizontal scale, refers to the time of each grid in
the horizontal direction of the screen. It is usually expressed in s/div. The adjustable
range of the horizontal timebase is related to the model type.
While you change the horizontal timebase, the displayed waveforms of all channels
are expanded or compressed horizontally relative to the current selected horizontal
reference baseline (refer to "Horizontal Expansion"). The horizontal timebase at
the upper-left corner of the screen will be changed accordingly, as shown in the
figure below.
You can adjust the horizontal timebase with the following three methods:
Rotate Horizontal
SCALE to adjust the horizontal timebase within the
available range (clockwise to reduce the horizontal timebase and
counterclockwise to increase).
Enable the touch screen function and adjust the horizontal timebase with the
pinch & stretch gesture on the touch screen. For details, refer to the "Pinch &
Stretch" section.
Enable the touch screen function, and tap the horizontal timebase label
at the top of the screen. The following window is displayed. Tap the
icon at the right side of the Scale input field to decrease or increase the
horizontal scale. You can also tap the Scale input field to input a specific value
with the displayed numeric keypad.
In the Horizontal control area (Horizontal), rotate the Horizontal
SCALE knob
to switch the adjustment mode between "Coarse" and "Fine" (by default, it is Coarse).
You can also press Acquire Fine to enable or disable the fine adjustment of the
horizontal timebase.
Coarse adjustment: Rotate the Horizontal SCALE knob will adjust the
horizontal timebase of the waveforms of all channels at 1-2-5 step within the
adjustable range. Rotate it clockwise to reduce the horizontal timebase, and
counterclockwise to increase the horizontal timebase.
Fine adjustment: Rotate the Horizontal SCALE knob will adjust the
horizontal timebase of the waveforms of all channels with a minor step value
within the adjustable range. Rotate it clockwise to reduce the horizontal
Decrease the timebase Increase the timebase