Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 20 Remote Control RIGOL
MSO5000-E User Guide 20-1
Chapter 20 Remote Control
The oscilloscope can be remotely controlled in the following three methods:
User-defined programming
You can program and control the oscilloscope by using the SCPI (Standard
Commands for Programmable Instruments) commands. For details about the
relevant commands and programming, refer to
MSO5000-E Series Programming
Guide
.
PC software
You can use the PC software to send commands to control the oscilloscope remotely.
RIGOL Ultra Sigma is recommended. You can download the software from RIGOL
official website (www.rigol.com).
Operation Procedures:
(1) Set up communication between the instrument and PC.
(2) Run Ultra Sigma and search for the instrument resource.
(3) Open the remote command control panel to send commands.
Web Control
MSO5000-E series digital oscilloscope supports Web Control. When the instrument is
connected to the internet, Web Control can display the waveform interface of the
oscilloscope in a real-time manner. You can migrate the instrument control and
waveform analysis to the control terminals (e.g. PC, mobile, and iPad) through Web
Control to realize remote control of the instrument. When you log in to the Web
Control for the first time, use the user name "admin" (without quotation marks) and
the password "rigol" (without quotation marks).
The oscilloscope can communicate with the PC via the following interfaces:
Remote Control via USB
Remote Control via LAN
Remote Control via GPIB
This chapter will illustrate how to use RIGOL's Ultra Sigma software to remotely
control the oscilloscope via various interfaces.
CAUTION
Before setting up communication, please turn off the instrument to avoid
causing damage to the communication interfaces.