Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 19 System Utility Function Setting
19-6 MSO5000-E User Guide
To Set the GPIB Address
Before using the GPIB bus to control the oscilloscope, use the USB-GPIB interface
converter (an option that requires to be ordered separately) to extend the GPIB
interface, and then use the GPIB cable to connect the instrument to the PC. Press
Utility IO GPIB, then rotate the multifunction knob directly to set the
GPIB address or use the pop-up numeric keypad to input the GPIB address. Its
settable range is from 1 to 30. By default, it is 1.
To Set HDMI
Sets the status and parameters of the HDMI video output interface on the rear panel.
Note that only when the HDMI interface is connected, can this menu be enabled.
Press HDMI to enter the HDMI setting menu.
Press Output continuously to enable or disable the video output.
ON: You can connect the instrument to an external display via this interface
to better observe the waveform display clearly from the external display.
OFF: disables the interface.
Press Resolution to set the screen resolution. The available resolution includes
640x480, 720x480, and 1280x720.
USB Connection
The oscilloscope can communicate with a PC via the USB DEVICE interface on the
rear panel. No parameters are required to be configured.