Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 17 Function/Arbitrary Waveform Generator (Option)
17-18 MSO5000-E User Guide
the range is from 0 s to 500 s.
End Keep
End keep indicates the time that the output signal continues outputting at
the "End Freq" after the Function/Arbitrary Waveform Generator sweeps
from "Start Freq" to "End Freq".
Press End Keep, then rotate the multifunction knob or use the pop-up
numeric keypad to set the end keep time. The default is 0 s, and the range
is from 0 s to 500 s.
Set the step
When the sweep type is set to "Step", this menu is enabled and can be
settable. Press Step number, then rotate the multifunction knob or
use the pop-up numeric keypad to set the step value. By default, it is 2. Its
available range is from 2 to 1000.
Set the trigger source
The trigger sources of the sweep can be Internal or Manual. When the
Function/Arbitrary Waveform Generator receives a trigger signal, a sweep
output is generated, and then it waits for another trigger signal.
Press Trig Source and rotate the multifunction knob to select the
desired trigger source, and then press down the knob to select it. You can
also press Trig Source continuously or enable the touch screen to select it.
The available trigger sources include Internal and Manual.
Internal: the Function/Arbitrary Waveform Generator outputs
continuous sweep waveforms.
Manual: when you press Manual Trig for one time, one sweep is
immediately launched for the corresponding channel.
3. Set the Sweep Time
Press Sweep Time, then rotate the multifunction knob or use the pop-up
numeric keypad to set the sweep time. By default, it is 1 s. Its available range is
from 1 ms to 500 s. After modifying the sweep time, the Function/Arbitrary
Waveform Generator will restart to output from the specified "Start Freq".
4. Set the Return Time
Return time indicates the time that the output signal restores from "End Freq" to
"Start Freq" after the Function/Arbitrary Waveform Generator sweeps from
"Start Freq" to "End Freq" and the "End Keep" time expires.
Press Return Time, then rotate the multifunction knob or use the pop-up
numeric keypad to set the return time. By default, it is 0 s. Its available range is
from 0 s to 500 s.