Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 17 Function/Arbitrary Waveform Generator (Option) RIGOL
MSO5000-E User Guide 17-11
select "Offset" or "Low Level". You can also press Offset or Low Level
continuously to select it. Also, you can enable the touch screen to select it.
Rotate the multifunction knob
or use the pop-up numeric keypad to set the
offset or low level value of the current signal.
Set the initial number of points
The initial number of points indicates the number of editable points. By default,
the number of editable points of arbitrary waveforms created can be preset to 2.
Point 1 is fixed at 0 s and Point 2 is fixed at the middle of the period. Press Init
Points, then rotate the multifunction knob or use the pop-up numeric
keypad to set the number of editable points for the arbitrary waveform. The
maximum number of editable points supported by the system is 16,384 (16
kpts).
Linear interpolation
Press Linear Interp to enable or disable the linear interpolation between the
defined points of the waveform.
ON: the waveform editor connects two points using a straight line.
OFF: the waveform editor will keep a constant voltage level between two
points and create a ladder-like waveform.
Edit points
Press Edit Points to enter the point editing menu. You can specify the voltage
value for each waveform point to define the waveforms.
Current Point
Press PointX, then rotate the multifunction knob or use the pop-up
numeric keypad to select the points to be edited. The available range is
from 1 to the number of initial points.
Voltage
Press Voltage, then rotate the multifunction knob or use the pop-up
numeric keypad to set the voltage value of the current point. Its available
range is from -2.5 V to +2.5 V.
Insert
Press Insert to insert a new editable point in the middle position between
the current editing point and the next editing point. The number of initial
points adds 1 automatically. You can press Insert continuously to increase
the editable points gradually.
Delete
Press Delete to delete the current point from the waveform, and connect
the remaining points with the current interpolation method.
Note: The 1
st
Point cannot be deleted.
Zoom
Press Zoom continuously to enable or disable the zoom function of
horizontal timebase.