Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 16 Display Control RIGOL
MSO5000-E User Guide 16-3
To Set the Waveform Intensity
Press Intensity, then rotate the multifunction knob at a small step value or use
the pop-up numeric keypad to set the waveform intensity. Note that in the non-menu
operation mode, you can also rotate the multifunction knob
to adjust the
waveform brightness of the channel. The default is 50%, and the range available is
from 1% to 100%.
To Set the Screen Grid
Press Grid, and rotate the multifunction knob to set the grid type and then press
down the knob to select it. You can also press Grid continuously or enable the touch
screen to select it. You can select "FULL", "HALF", "NONE", or "IRE".
FULL: turns the background grid and coordinate on.
HALF: turns the background grid off.
NONE: turns the background grid and coordinate off.
IRE: only available for testing the video signal (i.g. the trigger type is set to
"Video" trigger, and the vertical scale is set to 140 mV).
When "IRE" is selected, the screen displays the vertical graticule in IRE and
marks it at the left side of the screen. Its range is from -40 IRE to +100 IRE.
Meanwhile, 0.35 V and 0.7 V levels are displayed at the right side of the screen,
as shown in the following figure.
To Set the Grid Brightness
Press Brightness, then rotate the multifunction knob at a small step value or
use the pop-up numeric keypad to set the grid intensity. The default is 20%, and the