Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 15 Search and Navigation Function RIGOL
MSO5000-E User Guide 15-3
and SDA.
SPI: Press Type to select "SPI" as the search type. For SPI Set menu
settings, refer to descriptions in "
SPI Trigger (Option)". Press
Threshold to enter the threshold setting menu. Rotate the multifunction
knob
or use the pop-up numeric keypad to set the thresholds of SCL,
SDA, and CS.
3. Copy Trigger
Copy to Trigger
Press More To Trigger to copy the selected search type to the same
trigger type. For example, if the current search type is "Edge", press To
Trigger to copy the edge search settings to the "Edge Trigger" settings.
From Trigger
Press More From Trigger to copy from the trigger settings of the
selected search type to the search settings. For example, if the current
trigger type is "Edge Trigger", press From Trigger to copy from the
Edge trigger settings to the "Edge" search settings.
Note: If you select "From Trigger", you need to set the search type first,
and then copy the trigger type settings from the trigger menu.
4. Open or Close the Mark Table
Press MarkTable continuously to enable or disable the display of the mark table.
The mark table is shown as below. You can also enable the touch screen to tap
the icon
at the right-upper corner of the table to close it.
5. Navigation
Press Navigation, then rotate the multifunction knob or use the pop-up
numeric keypad to set the event No. to navigate the event. You can also use the
navigation combination keys to make navigations at a step of 1. For details, refer