Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 11 Protocol Decoding
11-34 MSO5000-E User Guide
desired baud rate.
Set the signal type
Press Signal and rotate the multifunction knob to select a signal type
that matches the actual FlexRay bus signal. Press down the knob to select it.
You can also press Signal continuously or enable the touch screen to select
it. The available signal types include BP, BM, and RX/TX.
Sample Position:
Sample position is a point within a bit’s time. The oscilloscope samples the
bit level at this point. The sample position is represented by the proportion
of "the time from the start of the bit to the sample position" to the "bit time",
as shown in the figure below.
Figure 11-12 Sample Position
Press Sample Position, then rotate the multifunction knob or use the
pop-up numeric keypad to set the sample position. The settable range is
from 10% to 90%.
5. Display-related setting
Press Display to enter the display setting menu.
Set the display format
Press Format, rotate the multifunction knob to select the display
format of the bus data. Then, press down the knob to select it. You can also
press Format continuously or enable the touch screen to select it. The
available display formats of the bus data are "Hex", "Dec", "Bin", and
"ASCII".
Adjust the vertical position of the bus
Press Position, and then rotate the multifunction knob to adjust the
vertical display position of the bus.
Set the label display
Press Label to enable or disable the label display of the FlexRay decoding
bus. When enabled, the bus label "FlexRay" will be displayed at the
upper-left side of the bus (when the bus display is enabled).
One Bit
60%
70%
80%