Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 11 Protocol Decoding RIGOL
MSO5000-E User Guide 11-5
polarity for data decoding.
4. Display-related setting
Press Display to enter the display setting menu.
Set the display format
Press Format, rotate the multifunction knob to select the display
format of the bus data. Then, press down the knob to select it. You can also
press Format continuously or enable the touch screen to select it. The
available display formats of the bus data are "Hex", "Dec", "Bin", and
"ASCII".
Adjust the vertical position of the bus
Press Position, and then rotate the multifunction knob to adjust the
vertical display position of the bus.
Set the label display
Press Label to enable or disable the label display of the Parallel decoding
bus. When enabled, the bus label "Parallel" will be displayed at the
upper-left side of the bus (when the bus display is enabled).
Event table
Press Event Table to enter the event table setting menu. The event table
displays the detailed decoding information in time order in the form of a
table, so as to better observe the long decoded data. The decoding
information includes the decoded data, the corresponding line number, and
time information.
Open or close the event table: Press Event Table continuously to
enable or disable the event table. When you enable the event table,
the following figure is displayed, as shown in
Figure 11-2. You can also
enable the touch screen to tap the icon
at the upper-right corner of
the table to close the event table. Besides, you can also rotate the
multifunction knob
to select a specified line and view the
corresponding decoding information.