Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 11 Protocol Decoding
11-4 MSO5000-E User Guide
automatically, and you cannot
modify them.
User
1-20,
by
default,
16
0 (default)
D15
(default)
Bit0 to Bit19 are set to D15 to
CH1 respectively.
Set the width
When BUS is set to "User", you can set the bus width. Press Width, rotate
the multifunction knob
or use the pop-up numeric keypad to set the
width. The available range is from 1 to 20. By default, it is 16.
Specify data channel for each bit
When BUS is set to any digital channel, you can specify the data channel for
each bit.
Press Bit X, then rotate the multifunction knob or use the pop-up
numeric keypad to set the bit of the channel.
By default, 0 is selected. Its available range is from 0 to (width - 1).
Press CH, then rotate the multifunction knob to select a channel source.
Press down the knob to select it. You can also press CH continuously or
enable the touch screen to select it. The analog channel (CH1-CH2) and
digital channel (D0-D15) can all be selected as the channel source.
Set the threshold level
To judge logic "1" and logic "0" of the buses, you need to set a threshold for
each analog channel (CH1-CH2). When the channel signal amplitude is
greater than the preset threshold, it is judged as logic "1"; otherwise logic
"0". Press Threshold, rotate the multifunction knob or use the pop-up
numeric keypad to set the threshold.
Set the endian
Press Endian continuously to select "Normal" or "Invert" as the endian of
the bus.
Polarity
Press Polarity continuously to select Positive or Negative as the
Channel Logic Level
Channel Signal Amplitude
Threshold Level
1
0
0