Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 11 Protocol Decoding RIGOL
MSO5000-E User Guide 11-3
Falling : samples the channel data on the falling edge of the clock.
Both
: samples the channel data on both the rising edge and the
falling edge of the clock.
Set the threshold
When the clock signal is an analog channel (CH1-CH2), you need to set a
threshold. Press Threshold, rotate the multifunction knob or use the
pop-up numeric keypad to set the threshold.
3. Bus setting
Press Bus to enter the bus setting menu.
Set the bus
Press BUS to select the digital bus for Parallel decoding, as shown in the
following table.
Bus
Width
Bit X
Channel
Remarks
CH1
1
0
CH1
Width, Bit X, and CH are set
automatically, and you cannot
modify them.
CH2
1
0
CH2
Width, Bit X, and CH are set
automatically, and you cannot
modify them.
D7-D0
8
0 (default)
D0
(default)
Bit0 to Bit7 are set to D0 to D7
respectively. Width is set
automatically, and you cannot
modify them.
D15-D8
8
0 (default)
D8
(default)
Bit0 to Bit7 are set to D8 to D15
respectively. Width is set
automatically, and you cannot
modify them.
D15-D0
16
0 (default)
D0
(default)
Bit0 to Bit15 are set to D0 to
D15 respectively. Width is set
automatically, and you cannot
modify them.
D0-D7
8
0 (default)
D7
(default)
Bit0 to Bit7 are set to D7 to D0
respectively. Width is set
automatically, and you cannot
modify them.
D8-D15
8
0 (default)
D15
(default)
Bit0 to Bit7 are set to D15 to D8
respectively. Width is set
automatically, and you cannot
modify them.
D0-D15
16
0 (default)
D15
(default)
Bit0 to Bit15 are set to D15 to
D0 respectively. Width is set