Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 8 Power Analysis (Option) RIGOL
MSO5000-E User Guide 8-3
settings of the upper limit and lower limit.
Press Lower, then rotate the multifunction knob or use the pop-up
numeric keypad to set the lower limit. Increasing the lower limit to the
current middle value will automatically increase the middle value and upper
limit to keep them higher than the lower limit.
Press Default, and then the upper value, middle value, and lower value will
be restored to the defaults.
Set Count
Press Count, then rotate the multifunction knob or use the pop-up numeric
keypad to set the number of statistical times for power quality analysis. Its
range is from 2 to 5000. By default, it is 1,000.
Reset
Press Reset Stat. to clear the current data and execute statistics on the
measurement results again.
Open or Close the Results Display Window
Press Display continuously to enable or disable the display of the results.
When enabled, the statistical results will be displayed on the screen, as shown in
the figure below. You can also enable the touch screen to tap the icon
at the
right-upper corner of the statistical results window to close it.
Note: If you select "ON" under Display, the multiplication operation will be
enabled in the Math operation.
View the Connection Diagram
Press Tips, and then the connection diagram of the power quality analysis is
displayed on the screen. Please connect the cables according to the connection
method as shown in Figure 8-1. Press Tips again or enable the touch screen to
tap the icon
at the right-upper corner of the connection diagram window to
close it.