Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 6 Operations and Measurements
6-44 MSO5000-E User Guide
The available units include "Source" and "Percent(%)".
Source: measures the amplitude at Y Cursor (taking the channel
ground point as the reference). The measurement results include AY,
BY, and △Y (its unit is consistent with that of the current source).
Percent(%): measures ratio at Y Cursor. The measurement results
include AY, BY, and △Y, and they are all expressed in percentage.
This oscilloscope allows you to set the reference position for the ratio
according to your needs. After adjusting Y Cursor to a desired position,
press Set Reference to take the current cursor position as the
reference. The current positions of Cursor A and Cursor B are
respectively defined as "0%" and "100%". Meanwhile, two cursors (in
blue) that cannot be moved are displayed on the screen as the ratio
reference position (the ratio position at "0%" and "100%" are
respectively marked by a solid line and a dotted line). Before you set
manually, the oscilloscope adopts the default ratio reference position.
6. Set LA Type
When "LA" is selected under Source, you need to set the LA display type. Press
More and then press La Type continuously to select "HEX" or "BIN".
7. Measurement Example
Measure the period of a sine wave by using the manual cursor measurement
and auto measurement respectively. The measurement results are both 1 ms, as
shown in Figure 6-3.
Figure 6-3 Manual Cursor Measurement Example
Auto
Measurement
Cursor
Measurement