Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 6 Operations and Measurements
6-36 MSO5000-E User Guide
parameters.
2. Source Selection
For different measurement categories, the selection methods for measurement
sources are different.
Horizontal and vertical parameter measurement
Press Measure Add Source A, rotate the multifunction knob to
select the desired channel for measurement and press down the knob to
select it. You can also press Source A continuously or enable the touch
screen to select the current measurement source. The available channels
include CH1-CH2, Math1-Math4, and D0-D15.
Other (Delay and Phase) parameter measurement
Press Measure Add Source A (Source B) to set the two source
channels for the current measurement category. The available channels
include CH1-CH2, Math1-Math4, and D0-D15.
Note: When Source A is set to an analog channel (or a digital channel),
Source B can also be set to an analog channel (or a digital channel).
3. Indicator
Press Indicator to enable or disable the indicator. You can also press Measure
Remove Indicator to enable or disable the indicator. For details, refer to
descriptions in "
Measure Mode".
4. Measurement Settings
Press Measure Setting to enter the sub-menu of measurement.
Press Mode to select the measurement mode to "Normal" or
"Precision".
Tip
When you rotate the multifunction knob to switch from the
measurement parameter area to the measurement category area, you
need to press down the knob
to select the desired measurement
category.
In the measurement category area, rotate the multifunction knob
to
select "Analyze". The following figure is displayed. Select "Counter",
"DVM", or "UPA" (available when the power analysis option is installed) to
enter the corresponding function setting menu. For descriptionsn about
these functions, refer to relevant chapters.