Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 6 Operations and Measurements
6-34 MSO5000-E User Guide
gating area. The formula is shown as follows:
n
x
Average
n
i
i
∑
1
=
=
Wherein,
i
x
is the measurement result of the
i
th point, and
n
is the number
of points being measured.
11. VRMS: indicates the root mean square value on the whole waveform or in the
gating area. The formula is as follows:
n
x
RMS
n
i
i
∑
1
2
=
=
Wherein,
i
x
is the measurement result of the
i
th point, and
n
is the number
of points being measured.
12. Per.VRMS: indicates the root mean square value within a period. The formula is
as shown above.
13. Overshoot: indicates the ratio of the difference between the maximum value
and the top value of the waveform to the amplitude value.
14. Preshoot: indicates the ratio of the difference between the minimum value and
the base value of the waveform to the amplitude value.
15. Std. Dev: indicates the root-mean-square value of the waveforms, with the DC
component removed. The formula is shown as follows:
n
Averagex
DevS
n
i
i
∑
1
2
)(
.td
=
−
=
Wherein,
i
x
is the amplitude of the
i
th point,
Average
is the waveform average
value, and
n
is the number of the points being measured.
Other Parameters
1. Positive Slew Rate: On the rising edge, first calculate the difference between
the high value and the low value, then use the difference to divide the
corresponding time value to obtain the positive slew rate.
2. Negative Slew Rate: On the falling edge, first calculate the difference
between the low value and the high value, then use the difference to divide the
corresponding time value to obtain the negative slew rate.
3. Area: indicates the area of the whole waveform within the screen. The unit is
V*s. The area of the waveform above the zero reference (namely the vertical
offset) is positive, and the area of the waveform below the zero reference is
negative. The area measured is the algebraic sum of the area of the whole
waveform within the screen.
4. Period Area: indicates the area of the first period of waveform on the screen.
The unit is V*s. The area of the waveform above the zero reference (namely the
vertical offset) is positive, and the area of the waveform below the zero