Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 6 Operations and Measurements
6-30 MSO5000-E User Guide
6. -Width: indicates the time between the threshold middle value of a falling edge
to the threshold middle value of the next rising edge.
7. +Duty: indicates the ratio of the positive pulse width to the period.
8. -Duty:indicates the ratio of the negative pulse width to the period.
9. Tvmax: indicates the time that corresponds to the maximum value of the
waveform (Vmax).
10. Tvmin: indicates the time that corresponds to the minimum value of the
waveform (Vmin).
Note: The default values for threshold upper limit, threshold middle value, and
threshold low limit are 90%, 50%, and 10%, respectively. You can press Measure
Setting to enter the sub-menu to set the parameters.
Count Values
1. Positive Pulse Count: The number of positive pulses that rise from under the
threshold lower limit to above the threshold upper limit.
2. Negative Pulse Count: The number of negative pulses that fall from above
the threshold upper limit to below the threshold lower limit.
3. Rising Edge Count: The number of rising edges that rise from under the
threshold lower limit to above the threshold upper limit.
Positive Pulse Count = n
1 2 n
Negative Pulse Count = n
1 2 n
Threshold Upper Limit
Threshold Lower Limit
Threshold Upper Limit
Threshold Lower Limit