Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

RIGOL Chapter 6 Operations and Measurements
6-28 MSO5000-E User Guide
Press Peak to Peak to enable or disable the peak-peak priority setting.
This function is intended for the shifted signal. If there is a large deviation,
you can view the signal waveform in priority when you enable the function.
Press CH to select "All" or "Open".
If you select "All", press AUTO and the system will test the two analog
channels (CH1 and CH2) in sequence. If no signal is found on the channel,
then the channel is disabled; if a signal is found on the channel, adjust the
channel to an optimal scale to display the signal.
If you select "Open", press AUTO and the system will only test the enabled
channels.
Press Overlay to enable or disable the waveform overlay display function.
If enabled, waveforms of different channels will be displayed in the same
position of the screen; if disabled, waveforms of different channels will be
displayed on the screen from top to bottom in sequence.
Press Coupling to enable or disable the coupling hold function. If enabled,
after you press AUTO, the settings for the channel coupling remain
unchanged; if disabled, then the channel coupling is, by default, set to
"DC".
Press Password, and then the password reset dialog box is displayed, as
shown in the figure below. You can reset the password.
: Press this key to cancel the auto setting and recovers to the parameter
settings prior to pressing the AUTO key.
Note: The waveform auto setting function requires that the frequency of the signal
should be greater than or equal to 35 Hz, the amplitude greater than or equal to 5
mV. If not meeting the conditions, the waveform auto setting function may be invalid.
Tip
If you lock the Auto function and then exit the auto setting function
menu, you can press Utility More Auto Config to enter the auto
setting function menu again to unlock the Auto function.